| Type |
|
Electrically Operated Pressure−Relief Cartridge, Size 16 |
|
|
| Designation |
|
Pressure−relief cartridge for 2 electrically selectable pressures |
|
|
| Design |
|
Seated pilot stage, spool−type main stage with external pilot oil drain to 3 |
|
|
| Mounting method |
|
Screw−in cartridge (M42 x 2) |
|
|
| Size |
|
Nominal size 16 mm, cavity type EB with annular groove to ISO 7789−42−06−0−07 |
|
|
| Cavity type thread |
|
|
|
|
| Max operating pressure |
|
420 bar |
|
|
| Max flow rate |
|
350 l/min |
|
|
| Flow direction |
|
1 → 2, see symbol |
|
|
| Hydraulic fluid |
|
Hydraulic oils HL and HLP to DIN 51 524; for other fluids, please consult BUCHER |
|
|
Hydraulic fluid temperature range |
|
−25°C ... + 80 °C |
|
|
| Viscosity range |
|
10...500 mm²/s (cSt), recommended 15 ... 250 mm²/s (cSt) |
|
|
| Minimum fluid cleanliness |
|
20/18/15 to ISO 4406 |
|
|
| For mer informasjon |
|
Datablad --- Oversikt |
|
|